For use in control cabinets, Simple and fast
| Design | housing for DIN rail mounting |
| Application | Installation in control cabinets |
| Operating voltage [V] | 26.5...31.6 DC |
| Max. current consumption from AS-i [mA] | 250 |
| Additional voltage supply [V] | 20...30 DC |
| Max. current consumption from additional supply [mA] | 3000; (AUX) |
| Integrated watchdog | yes |
| Number of inputs and outputs | Number of digital inputs: 4; Number of digital outputs: 3 |
| Number of digital inputs | 4 |
| Input circuit of digital inputs | PNP; (type 2 according to IEC 61131-2) |
| Sensor supply of the inputs | AS-i |
| Voltage supply [V] | 18...30; (DC) |
| Max. total current rating of inputs [mA] | 200 |
| Input current High [mA] | 6...10 |
| Input current Low [mA] | 0...2 |
| Switching level high [V] | > 11 |
| Digital inputs protected against short circuits | yes |
| Number of digital outputs | 3 |
| Circuit | PNP |
| Voltage range DC [V] | 20...30; (AUX) |
| Max. current load per output [mA] | 1000; (utilisation category DC-12: 700 mA; utilisation category DC-13 (control of electromagnets): 20 W (IEC 60947-5-1)) |
| Total current rating of all outputs [A] | 3 |
| Short-circuit proof | yes |
| Electrically separated | yes |
| Actuator supply outputs | AUX |
| Ambient temperature [°C] | -25...70 |
| Note on ambient temperature | the derating of the current load indicated in the operating instructions is to be taken into account at the following ambient temperature: > 60 °C |
| Max. relative air humidity [%] | 90; (non condensing) |
| Max. height above sea level [m] | 2000 |
| Protection | IP 20 |
| Pollution degree | 2 |
| EMC | EN 61000-6-2; EN 62026-2; EN 50581 |
| MTTF [years] | 182 |
| Notes | The device shall be supplied from an isolating source.; This voltage source must have a secondary UL-listed fuse (see enclosed sheet).; Alternatively, a class 2 power supply can be used to supply AUX. |
| AS-i version | 2.11; 3.0 |
| AS-i addressing | addressing socket |
| Extended addressing mode | yes |
| AS-i I/O configuration [hex] | 7 |
| Assignment of the data bits | data bit: D0: D1: D2: D3; input: I-1: I-2: I-3: I-4; Output: O-1: O-2: O-3: - |
| Weight [g] | 146 |
| Housing | rectangular |
| Type of mounting | mounting on DIN rail; (TH35 (EN 60715)) |
| Dimensions [mm] | 93 x 25.4 x 108 |
| Materials | PC-GF20 |
| Display | switching status: LED, yellow I1...I4, O1....O3; operation: LED, green AS-i, AUX; errors: LED, red |
| Accessories (optional) | connectors |
| Remarks | Do not connect any of the following points to an external potential:; I-, I+, I1, I2, I3, I4; The connections are electrically connected with the AS-i cable. |