Артикул: 231221 Производитель: Pepperl+Fuchs

CI-K2X-145-TS-NA

Под заказ
RUСклад на Домостроительной 3Д
нет в наличии
CNСклад в Китае
нет предложений
EUСклад в Европе
4 757.20 ₽
срок ≈2 нед. (14 дн.)
ITИталия
34.40 €
срок ≈2 нед. (14 дн.)
ROРумыния
1 032.93 €
срок ≈1 мес. (49 дн.)

Цены в валюте поставщика с нашей наценкой, без учёта логистики. Самовывоз со склада поставщика за рубежом.

1-channel isolated barrier, 24 V DC supply (P

Signal typeAnalog input
ConnectionOutput I: terminals 10, 11, 12; Output II: terminals 16, 17, 18; Output III: terminals 7-, 8+, 9-
Ripplewithin the supply tolerance
Power consumptionmax. 3 W
TypeRS-485
Programming interfaceprogramming socket
Lead resistancemax. 25 Ω per line
Sensor supply1 ... 5 V
Short-circuit current50 mA
Load≥ 116 Ω up to 5V, ≥ 85 Ω up to 4V
Connection sidecontrol side
Programmable Tare0 ... 500 % of span
Input Iterminals 1+, 2- Ex ia IIC, Ex iaD
Input signal-100 ... 100 mV
Input resistance> 1 MΩ for voltage measurement
Input II, IIItare adjustment, calibration and zero
Open circuit voltage/short-circuit current18 V / 5 mA
Active/PassiveI > 4 mA/I < 1.5 mA
Output I, IIterminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
Contact loading253 V AC/2 A/500 VA/cos φ min. 0.7; 40 V DC/2 A resistive load
Mechanical life2 x 107 switching cycles
Output IIIterminals 7-, 8+, 9- non-intrinsically safe
Current range-20 ... 20 mA
Analog voltage output0 ... ± 10 V; output resistance 500 Ω (bridge between terminal 7 and 9)
Analog current output0 ... ± 20 mA or 4 ... 20 mA; load 0 ... 550 Ω (terminals 7 and 8)
Line fault detectiondownscale -21.5 mA (-10.75 V) or 2 mA (1 V), upscale 21.5 mA (10.75 V)
Collective error messagePower Rail
Resolution/accuracy≤ ± 0.05 % incl. non-linearity and hysteresis
Temperature effect≤ ± 0.01 %/K
Reaction time300 ... 850 ms
Input I/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachotherreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/Input II, IIInot available
Output III/Programming socketnot available
Other circuits from each otherfunctional insulation, rated insulation voltage 50 Veff
Display elementsLEDs , display
Control elementsControl panel
Configurationvia operating buttons via PACTware
Labelingspace for labeling at the front
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Directive 2014/35/EUEN 61010-1:2010
Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Massapprox. 250 g
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Height119 mm
Width40 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
SupplyPower Rail or terminals 23+, 24- non-intrinsically safe
Voltage Uo14 V
Current Io238 mA
Power Po833 mW (linear characteristic)
Input II and IIIterminals 13+, 14-; 15+, 14- non-intrinsically safe
Maximum safe voltage Um40 V DC (Attention! Um is no rated voltage.)
InterfaceRS 485 programming jack
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012

Информация об аналогах собирается и скоро появится здесь.

Отгрузка со склада на Домостроительной ул., 3Д (Санкт-Петербург) — в день заказа при наличии товара. Доставка по России транспортными компаниями — обычно 1–7 рабочих дней в зависимости от региона. Точный срок и стоимость доставки рассчитает менеджер при оформлении заявки.

Поставка из-за рубежа (под заказ)

СкладЦенаСрокНаличие
Склад в Европе 4 757.20 ₽ ≈2 нед. (14 дн.) под заказ
Склад в Европе 142 854.40 ₽ ≈1 мес. (49 дн.) под заказ