Артикул: 200913 Производитель: Pepperl+Fuchs

AS-Interface sensor/actuator module VBA-4E4A- 200913

Под заказ
RUСклад на Домостроительной 3Д
нет в наличии
CNСклад в Китае
нет предложений
EUСклад в Европе
34 605.91 ₽
срок ≈1 мес. (49 дн.)
ROРумыния
250.22 €
срок ≈1 мес. (49 дн.)

Цены в валюте поставщика с нашей наценкой, без учёта логистики. Самовывоз со склада поставщика за рубежом.

KE switch cabinet module, 4 inputs (PNP) and

Node typeA/B node
AS-Interface specificationV3.0
Required gateway specification≥ V3.0
IO code7
ID1 code7
ID2 code7
LED FAULTFault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supply
LED INTInternal input supply active; LED green
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 4 LED yellow
LED OUTSwitching state (output); 4 LED yellow
Surge protectionO1 ... O4: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV)
Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT)
Voltage21 ... 31 V DC (INT)
Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT)
Input current≤ 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)≤ 2 mA
1 (attenuated)≥ 4 mA
Signal delay< 2 ms (input/AS-Interface)
Per contact2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V AC
Per module8 A
Control circuit≤ 8 mA per relay (from AS-Interface)
Switching delay< 10 ms (AS-Interface/contact)
Usage categoryDC-13 and AC-14
Mechanical5 x 106
Electrical0.2 x 106 (250 V AC, 2 A, cos φ = 0.4)
Overload protectionfuse unit 2 A required in the load current circuit
Input/Outputsafe isolation, rated insulation voltage 300 V AC
Input/AS-InterfaceSwitch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC
Output/Outputbasic insulation, rated insulation voltage 300 V AC
Output/AS-Interfacesafe isolation, rated insulation voltage 300 V AC
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-4:2007 EN 61326-1:2006
Directive 73/23/EECEN 60947-1:2007
Galvanic isolationEN 60947-1:2007
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
InputEN 61131-2:2004
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Pollution degree2
Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
HousingPA 66-FR
Mass170 g
Height99 mm
Width22.5 mm
Length102 mm
MountingDIN mounting rail
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm

Информация об аналогах собирается и скоро появится здесь.

Отгрузка со склада на Домостроительной ул., 3Д (Санкт-Петербург) — в день заказа при наличии товара. Доставка по России транспортными компаниями — обычно 1–7 рабочих дней в зависимости от региона. Точный срок и стоимость доставки рассчитает менеджер при оформлении заявки.

Поставка из-за рубежа (под заказ)

СкладЦенаСрокНаличие
Склад в Европе 34 605.91 ₽ ≈1 мес. (49 дн.) под заказ