AS-Interface sensor/actuator module VBA-4E4A- 200913
Под заказ
RUСклад на Домостроительной 3Д
нет в наличии
CNСклад в Китае
нет предложений
EUСклад в Европе
34 605.91 ₽
срок ≈1 мес. (49 дн.)
ROРумыния
250.22 €
срок ≈1 мес. (49 дн.)
Цены в валюте поставщика с нашей наценкой, без учёта логистики. Самовывоз со склада поставщика за рубежом.
KE switch cabinet module, 4 inputs (PNP) and
| Node type | A/B node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V3.0 |
| IO code | 7 |
| ID1 code | 7 |
| ID2 code | 7 |
| LED FAULT | Fault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supply |
| LED INT | Internal input supply active; LED green |
| LED PWR | AS-Interface voltage; LED green |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching state (output); 4 LED yellow |
| Surge protection | O1 ... O4: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV) |
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
| Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
| Voltage | 21 ... 31 V DC (INT) |
| Current loading capacity | ≤ 150 mA, overload- and short-circuit protected (INT) |
| Input current | ≤ 8 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated) | ≤ 2 mA |
| 1 (attenuated) | ≥ 4 mA |
| Signal delay | < 2 ms (input/AS-Interface) |
| Per contact | 2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V AC |
| Per module | 8 A |
| Control circuit | ≤ 8 mA per relay (from AS-Interface) |
| Switching delay | < 10 ms (AS-Interface/contact) |
| Usage category | DC-13 and AC-14 |
| Mechanical | 5 x 106 |
| Electrical | 0.2 x 106 (250 V AC, 2 A, cos φ = 0.4) |
| Overload protection | fuse unit 2 A required in the load current circuit |
| Input/Output | safe isolation, rated insulation voltage 300 V AC |
| Input/AS-Interface | Switch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC |
| Output/Output | basic insulation, rated insulation voltage 300 V AC |
| Output/AS-Interface | safe isolation, rated insulation voltage 300 V AC |
| Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-4:2007 EN 61326-1:2006 |
| Directive 73/23/EEC | EN 60947-1:2007 |
| Galvanic isolation | EN 60947-1:2007 |
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2004 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , non-condensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 2 |
| Connection | removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2 |
| Housing | PA 66-FR |
| Mass | 170 g |
| Height | 99 mm |
| Width | 22.5 mm |
| Length | 102 mm |
| Mounting | DIN mounting rail |
| Tightening torque of clamping screws | 0.5 Nm ... 0.6 Nm |
Информация об аналогах собирается и скоро появится здесь.
Отгрузка со склада на Домостроительной ул., 3Д (Санкт-Петербург) — в день заказа при наличии товара. Доставка по России транспортными компаниями — обычно 1–7 рабочих дней в зависимости от региона. Точный срок и стоимость доставки рассчитает менеджер при оформлении заявки.
Поставка из-за рубежа (под заказ)
| Склад | Цена | Срок | Наличие |
|---|---|---|---|
| Склад в Европе | 34 605.91 ₽ | ≈1 мес. (49 дн.) | под заказ |