The TF42-2.3 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.

Варианты поставки

СкладЦенаСрокНаличиеМин. партия
Склад в Китае 2 409.37 ₽ ≈2 мес. (73 дн.) под заказ — Заказать
Склад в Китае 2 863.63 ₽ ≈1 мес. (45 дн.) под заказ — Заказать
Склад в Европе 3 112.55 ₽ ≈4 мес. (122 дн.) под заказ — Заказать
Склад в Китае 3 435.93 ₽ ≈4 мес. (122 дн.) под заказ — Заказать
Склад в Европе 3 595.01 ₽ ≈2 мес. (73 дн.) под заказ — Заказать
Склад в России 3 673.91 ₽ 5 дн. 5 шт. — Заказать
Склад в Европе 3 690.86 ₽ ≈1 мес. (38 дн.) под заказ — Заказать
Склад в Европе 4 003.30 ₽ ≈1 мес. (59 дн.) под заказ — Заказать
Склад в Китае 4 074.33 ₽ ≈1 мес. (38 дн.) под заказ — Заказать
Склад в Китае 4 095.92 ₽ ≈2 мес. (73 дн.) под заказ — Заказать
Склад в Европе 4 409.98 ₽ ≈1 мес. (45 дн.) под заказ — Заказать
Склад в Китае 4 419.23 ₽ ≈1 мес. (59 дн.) под заказ — Заказать
Склад в Китае 4 868.16 ₽ ≈1 мес. (45 дн.) под заказ — Заказать
Склад в Европе 5 548.11 ₽ уточняется под заказ — Заказать

Характеристики

Minimum Order Quantity1 piece
Customs Tariff Number85364900
Product Net Width45 mm
Product Net Height88.3 mm
Product Net Depth / Length70.5 mm
Product Net Weight0.13 kg
Setting Range1.7 ... 2.3 A
Rated Operational VoltageAuxiliary Circuit 600 V AC/DC, Main Circuit 690 V AC, Main Circuit 600 V DC
Rated Operational Current (Ie)2.3 A
Rated Frequency (f)Auxiliary Circuit 50 Hz, Auxiliary Circuit 60 Hz, Auxiliary Circuit DC, Main Circuit 50 Hz, Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV, Main Circuit 6 kV
Rated Insulation Voltage (Ui)690 V
Number of Poles3P
Number of Auxiliary Contacts NC1
Number of Auxiliary Contacts NO1
Number of Protected Poles3
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit NC 6 A, Auxiliary Circuit NO 4 A
Rated Operational Current AC-15 (Ie)(120 V) NC 3 A, (120 V) NO 0.5 A, (240 V) NC 3 A, (240 V) NO 0.5 A, (400 V) NC 0.75 A, (400 V) NO 0.5 A, (500 V) NC 0.75 A, (500 V) NO 0.5 A
Rated Operational Current DC-13 (Ie)(125 V) NC 0.55 A, (125 V) NO 0.55 A, (24 V) NC 1.25 A, (24 V) NO 1.25 A, (250 V) NC 0.27 A, (250 V) NO 0.27 A, (500 V) NC 0.15 A, (500 V) NO 0.15 A, (60 V) NC 0.55 A, (60 V) NO 0.55 A
Degree of ProtectionIP20
Pollution Degree3
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Flexible 1/2x 0.75 ... 1 mm², Flexible 1/2x 1 ... 2.5 mm², Rigid 1/2x 0.75 ... 4 mm²
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 0.75 ... 4 mm², Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm², Flexible 1/2x 0.75 ... 4 mm², Rigid 1/2x 0.75 ... 4 mm²
Tightening TorqueAuxiliary Circuit 1 ... 1.2 N·m, Main Circuit 1.5 ... 2.5 N·m
Wire Stripping LengthAuxiliary Circuit 9 mm, Main Circuit 12 mm
Recommended Screw DriverMain Circuit Pozidriv 2
Power Lossat Rated Operating Conditions per Pole 1.1 ... 2.0 W
Suitable ForAF09, AF12, AF16, AF26, AF30, AF38
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-4-1, IEC 60335-2-40 A2L
Maximum Operating Voltage UL/CSAMain Circuit 600 V AC
Contact Rating UL/CSA(NC:) B600, (NC:) Q600, (NO:) Q600, (NO:) D300
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 18-10 AWG, Stranded 1/2x 18-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-12 AWG, Stranded 1/2x 18-12 AWG
Tightening Torque UL/CSAAuxiliary Circuit 9 ... 11 in·lb, Main Circuit 13 ... 22 in·lb
Ambient Air TemperatureOperation -25 ... +60 °C, Operation Compensated -25 ... +60 °C, Storage -50 ... +80 °C
Ambient Air Temperature CompensationYes
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 ... 150 Hz
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
Improved Energy Efficiency for CustomersProduct Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 65 %
Package Level 1 Unitscarton 1 piece
Package Level 1 Width48 mm
Package Level 1 Height92 mm
Package Level 1 Depth / Length78 mm
Package Level 1 Gross Weight0.145 kg
Package Level 2 Unitscarton 40 piece
Package Level 2 Width280 mm
Package Level 2 Height210 mm
Package Level 2 Depth / Length395 mm
Package Level 2 Gross Weight7.346 kg
Object Classification CodeF
ETIM 9EC000106 - Thermal overload relay
ETIM 10EC000106 - Thermal overload relay
eClassV11.0 : 27371501