Артикул: 1SAH102016R9900 · Производитель: ABB · EAN: 4013614545801

1SAH102016R9900

Под заказ
Наличие в РФ
нет в наличии
Склад в Китае
2 109.65 ₽
срок ≈1 мес. (45 дн.)
Склад в Европе
2 273.33 ₽
срок ≈1 мес. (38 дн.)
Запросить цену / заказать
The MCRA040AT4 mini contactor relay is a dimension optimized 4 pole contactor relay with screw terminals. This device is a great solution when high performances are needed but the space is limited. Mini contactors are used in residential buldings, commercial buildings and industrial applications for switching of control signals up to 6 A / 240 V (AC-15). The product is suitable for wall or rail mounting.

Варианты поставки

СкладЦенаСрокНаличиеМин. партия
Склад в Китае 2 109.65 ₽ ≈1 мес. (45 дн.) под заказ — Заказать
Склад в Европе 2 273.33 ₽ ≈1 мес. (38 дн.) под заказ — Заказать
Склад в Китае 2 509.52 ₽ ≈1 мес. (38 дн.) под заказ — Заказать
Склад в Европе 2 733.37 ₽ ≈4 мес. (122 дн.) под заказ — Заказать
Склад в Европе 2 772.24 ₽ ≈1 мес. (59 дн.) под заказ — Заказать
Склад в Китае 3 017.36 ₽ ≈4 мес. (122 дн.) под заказ — Заказать
Склад в Китае 3 060.27 ₽ ≈1 мес. (59 дн.) под заказ — Заказать
Склад в Европе 3 150.57 ₽ уточняется под заказ — Заказать
Склад в Европе 3 248.86 ₽ ≈1 мес. (45 дн.) под заказ — Заказать
Склад в Китае 3 477.90 ₽ ≈33 мес. (1009 дн.) под заказ — Заказать
Склад в Китае 3 586.41 ₽ ≈1 мес. (45 дн.) под заказ — Заказать
Склад в Европе 3 909.69 ₽ уточняется под заказ — Заказать

Характеристики

Minimum Order Quantity1 piece
Customs Tariff Number85365080
Product Net Width45 mm
Product Net Depth / Length56 mm
Product Net Height48 mm
Product Net Weight0.17 kg
Number of Main Contacts NO0
Number of Main Contacts NC0
Number of Auxiliary Contacts NO4
Number of Auxiliary Contacts NC0
Number of Poles4P
StandardsIEC/EN 60947-1, IEC/EN 60947-5-1, UL 60947-1, UL 60947-5-1
Rated Operational VoltageAuxiliary Circuit 690 V AC, Auxiliary Circuit 440 V DC
Rated Frequency (f)Auxiliary Circuit 50 Hz, Auxiliary Circuit 60 Hz, Auxiliary Circuit DC, Control Circuit 50 Hz, Control Circuit 60 Hz
Conventional Free-air Thermal Current (Ith)Auxiliary Circuit 10 A
Rated Operational Current AC-15 (Ie)(240 V) 6 A, (400 V) 4 A, (500 V) 2.5 A, (690 V) 1.5 A
Rated Operational Current DC-13 (Ie)(24 V) 5 A, (48 V) 2.5 A, (125 V) 0.55 A, (250 V) 0.3 A, (440 V) 0.15 A
Short-Circuit Protective DevicesgG Type Fuses 10 A
Rated Insulation Voltage (Ui)750 V
Rated Impulse Withstand Voltage (Uimp)Auxiliary Circuit 6 kV
Maximum Electrical Switching Frequency(AC-15) 360 cycles per hour, (DC-13) 360 cycles per hour
Mechanical DurabilityNr. Operations 10000000 cycle
Minimum Switching CapacityAuxiliary Circuit 17 V, Auxiliary Circuit 5 mA
Coil Operating Limits(acc. to IEC 60947-5-1) for AC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)120 V AC
Coil ConsumptionAverage Holding Value 50 Hz 5.3 V·A, Average Pull-in Value 50 Hz 5.3 V·A
Power Lossat Rated Operating Conditions per Pole 0.4 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm², Flexible with Ferrule 2x 0.75 ... 1.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Flexible 1/2x 0.75 ... 2.5 mm², Rigid 1x 0.75 ... 4 mm², Rigid 2x 0.75 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm², Flexible with Ferrule 2x 0.75 ... 1.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm², Flexible 1/2x 0.75 ... 2.5 mm², Rigid 1/2x 0.75 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 9 mm, Control Circuit 9 mm
Degree of ProtectionAuxiliary Circuit Terminals IP20, Control Circuit Terminals IP20, Main Circuit Terminals IP20
Recommended Screw DriverPozidriv 2
Tightening TorqueAuxiliary Circuit 0.8 ... 1.0 N·m, Control Circuit 0.8 N·m
Terminal TypeScrew Terminals
Mini Contactor TypeMini Contactor Relay
Product NameMini Contactor Relay
Maximum Operating Voltage UL/CSA600 V AC
General Use Rating UL/CSA(600 V AC) 10 A
Connecting Capacity Auxiliary Circuit UL/CSAStranded 1/2x 18-12 AWG
Contact Rating UL/CSAA600, Q600
Tightening Torque UL/CSAAuxiliary Circuit 7 in·lb, Control Circuit 7 in·lb, Main Circuit 7 in·lb
Ambient Air TemperatureOperation -40 ... +70 °C, Storage -55 ... +80 °C
Maximum Operating Altitude Permissible3000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 25g
Resistance to Vibrations5g 3 ... 150 Hz
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
Package Level 1 Unitsbox 1 piece
Package Level 1 Width46 mm
Package Level 1 Depth / Length49 mm
Package Level 1 Height58 mm
Package Level 1 Gross Weight0.175 kg
Package Level 2 Unitsbox 20 piece
Package Level 2 Width237 mm
Package Level 2 Depth / Length102 mm
Package Level 2 Height120 mm
Package Level 2 Gross Weight3.55 kg
Object Classification CodeK