Артикул: 1SBE111111M1411 · Производитель: ABB

1SBE111111M1411

Под заказ
Наличие в РФ
нет в наличии
Склад в Китае
2 440.41 ₽
срок ≈1 мес. (45 дн.)
Склад в Европе
2 378.88 ₽
срок ≈1 мес. (38 дн.)
Запросить цену / заказать
The ESB16..N installation contactors are used to control single loads up to 16 A and can be operated by AC or DC. These contactors are made for use in household applications as well as in industrial environments. The following benefits are provided: Hum-free operation, low power consumption and integrated overvoltage protection. Various contact combinations and accessories are available.

Варианты поставки

СкладЦенаСрокНаличиеМин. партия
Склад в Европе 2 378.88 ₽ ≈1 мес. (38 дн.) под заказ — Заказать
Склад в Китае 2 440.41 ₽ ≈1 мес. (45 дн.) под заказ — Заказать
Склад в Китае 2 626.04 ₽ ≈1 мес. (38 дн.) под заказ — Заказать
Склад в Европе 2 710.33 ₽ ≈1 мес. (59 дн.) под заказ — Заказать
Склад в Европе 2 806.98 ₽ ≈4 мес. (122 дн.) под заказ — Заказать
Склад в Китае 2 904.78 ₽ ≈1 мес. (59 дн.) под заказ — Заказать
Склад в Китае 3 098.62 ₽ ≈4 мес. (122 дн.) под заказ — Заказать
Склад в Европе 3 758.23 ₽ ≈1 мес. (45 дн.) под заказ — Заказать
Склад в Европе 3 953.01 ₽ уточняется под заказ от 12 шт. Заказать
Склад в Китае 4 148.70 ₽ ≈1 мес. (45 дн.) под заказ — Заказать

Характеристики

Minimum Order Quantity12 piece
Customs Tariff Number85365080
Product Net Width18 mm
Product Net Depth / Length65 mm
Product Net Height85 mm
Product Net Weight0.14 kg
Number of Main Contacts NO1
Number of Main Contacts NC1
Number of Auxiliary Contacts NO0
Number of Auxiliary Contacts NC0
Number of Poles2P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, IEC/EN 61095, IEC 60335-2-40 A2L
Rated Operational VoltageMain Circuit 220 V DC, Main Circuit 240 V AC
Rated Frequency (f)Control Circuit DC, Control Circuit 50 Hz, Control Circuit 60 Hz, Control Circuit 400 Hz, Main Circuit DC, Main Circuit 50 Hz, Main Circuit 60 Hz
Rated Operational Current AC-1 (Ie)(NC) 16 A, (NO) 16 A
Rated Operational Current AC-3 (Ie)(230 V) Single Phase, NC 6 A, (230 V) Single Phase, NO 6 A
Rated Operational Current AC-7a (Ie)(NC) 16 A, (NO) 16 A
Rated Operational Current AC-7b (Ie)(230 V) Single Phase, NC 6 A, (230 V) Single Phase, NO 6 A
Rated Operational Power AC-1 (Pe)(230 V) Single Phase, NC 3.7 kW, (230 V) Single Phase, NO 3.7 kW
Rated Operational Power AC-3 (Pe)(230 V) Single Phase, NC 0.9 kW, (230 V) Single Phase, NO 0.9 kW
Rated Operational Power AC-7a (Pe)(230 V) Single Phase, NC 3.7 kW, (230 V) Single Phase, NO 3.7 kW
Rated Operational Power AC-7b (Pe)(230 V) Single Phase, NC 0.9 kW, (230 V) Single Phase, NO 0.9 kW
Rated Breaking Capacity AC-38 x Ie / AC-3
Rated Making Capacity AC-310 x Ie / AC-3
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
Rated Insulation Voltage (Ui)400 V
Rated Impulse Withstand Voltage (Uimp)6 kV
Electrical DurabilityAC-1 (NC) 150000 cycle, AC-1 (NO) 150000 cycle, AC-3 (NC) 150000 cycle, AC-3 (NO) 150000 cycle, AC-7a (NC) 150000 cycle, AC-7a (NO) 150000 cycle, AC-7b (NC) 150000 cycle, AC-7b (NO) 150000 cycle
Maximum Electrical Switching Frequency(AC-1) 300 cycles per hour, (AC-3) 600 cycles per hour, (AC-7a) 300 cycles per hour, (AC-7b) 600 cycles per hour
Mechanical DurabilityNr. Operations 1000000 cycle
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
Rated Control Circuit Voltage (Uc)12 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 2.5 V·A, Average Holding Value DC 2.5 W, Average Pull-in Value 50 Hz 2.5 V·A, Average Pull-in Value 60 Hz 2.5 V·A, Average Pull-in Value DC 2.5 W
Power Lossat Rated Operating Conditions AC-1 per Pole NC 0.9 W, at Rated Operating Conditions AC-1 per Pole NO 0.9 W
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715, TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Connecting Capacity Main CircuitFlexible with Ferrule 1x 1 ... 6 mm², Flexible with Ferrule 2x 1 ... 2.5 mm², Flexible with Insulated Ferrule 1x 1 ... 6 mm², Flexible with Insulated Ferrule 2x 1 ... 1.5 mm², Flexible 1x 1 ... 6 mm², Flexible 2x 1 ... 4 mm², Rigid 1x 1 ... 10 mm², Rigid 2x 1 ... 4 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1x 0.75 ... 2.5 mm², Flexible with Ferrule 2x 0.75 ... 1.5 mm², Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm², Flexible with Insulated Ferrule 2x 0.75 ... 1 mm², Flexible 1x 1 ... 2.5 mm², Flexible 2x 1 ... 1.5 mm², Rigid 1x 0.5 ... 4 mm², Rigid 2x 0.75 ... 2.5 mm²
Wire Stripping LengthControl Circuit 7 mm, Main Circuit 10 mm
Degree of ProtectionIP20
Recommended Screw DriverControl Circuit Pozidriv 1, Main Circuit Pozidriv 1
Tightening TorqueControl Circuit 0.9 N·m, Main Circuit 1.2 N·m
Terminal TypeScrew Terminals
Width in Number of Modular Spacings1
Product NameInstallation Contactor
Maximum Operating Voltage UL/CSAMain Circuit 240 V AC
General Use Rating UL/CSA(acc. to UL 240 V) 16 A
Horsepower Rating UL/CSA(220 ... 240 V AC) Single Phase, NC 0.75 Hp, (220 ... 240 V AC) Single Phase, NO 0.75 Hp
Connecting Capacity Main Circuit UL/CSASolid 14-8 AWG, Stranded 14-8 AWG
Connecting Capacity Control Circuit UL/CSASolid 16-10 AWG, Stranded 16-10 AWG
Tightening Torque UL/CSAControl Circuit 8 in·lb, Main Circuit 11 in·lb
Full Load Amps Motor Use(220 ... 240 V AC) Single Phase, NC 6.9 A, (220 ... 240 V AC) Single Phase, NO 6.9 A
Ambient Air TemperatureOperation -25 ... +55 °C, Storage -40 ... +80 °C
Maximum Operating Altitude Permissible2000 m
Resistance to Shock acc. to IEC 60068-2-2711 ms Pulse 15g
Pollution Degree3
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2BBusiness To Consumer
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill